ELAN Home Systems 1690 Corporate Circle Petaluma, CA 94954 USA
tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: elan@elanhomesystems.com
©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.
Integration Note
Manufacturer: Aprilaire
Model Number(s): 8800 Thermostat
Minimum Core Module Version: g! 5.4.104
Document Revision Date: 2/14/2013
OVERVIEW AND SUPPORTED FEATURES
THE 8800 THERMOSTATS SUPPORT THE FOLLOWING FEATURES:
Temperature Control: Temperature control can be managed by schedules tied to house modes or by
manual control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold).
Temperature can be shown as either Fahrenheit or Celsius on the viewer interface.
Mode Control: The climate system can be set to run in the following heating and cooling modes: Heat
only, Cool only, Auto Heat Cool, Emergency Heat or Off.
Fan Mode Control: Systems that have a fan can be set to run in Automatic, Continuous or Circulate
mode.
History View: The history view shows the inside temperature, outside temperature, unit run and fan run
times, and cooling and heating set points.
Schedule Control: Multiple schedules can be set using the Viewer software and configured using the
configurator. Up to 10 schedules can be created and are tied to the system mode.
Outside Air Temperature: The outside air temperature can be obtained from the weather information on
the web, a sensor connected to the thermostat, or monitored using an 8081 or 8082 Support Module. The
outside air temperatures can be displayed in real-time or tracked in history for each thermostat in the
Viewer.
Humidity Display: Although humidity control is not supported, the humidity value can be obtained from a
humidity sensor in the 8800 in the thermostat and humidity mode; from a humidity sensor in the 8082, or
from the web. You can display the value on the history graph; on a custom graph using a Graph View
control, or as a custom text display using the Numeric text control. Note: If a thermostat is configured as a
humidistat, then it must be removed from all interfaces.
Auto Time and Date: The g! system will automatically update the time and date on the thermostats
including daylight savings time changes.
Auto Thermostat Detection: The g! system will automatically detect all the thermostats connected to
system, along with each thermostat’s ID (number).
Celsius and Fahrenheit: Aprilaire Thermostats support displaying Temperatures in C or F both at the
stat and in the g! system in whole number values. Decimal place display and control is not supported for
these thermostats.
Remote Room Temp Sensor connected directly to 8800 Thermostat: The 8800 can be configured to
utilize a remote temperature sensor in place of its on board sensor. The sensor connects directly to its T1
& T2 terminals. When properly connected and configured this sensor will override the onboard sensor
and the thermostat then reports the remote sensor value to the system controller as its room temperature
value. Please refer to the Aprilaire documentation for setup information.
Przeglądanie stron 0
1 2 3 4 5 6 ... 10 11

Podsumowanie treści

Strona 1 - Integration Note

ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: elan

Strona 2

10 of 11 g! CONFIGURATION DETAILS The following table provides settings used in the g! Configurator. In the table below: o “<Select>” Select

Strona 3 - INSTALLATION OVERVIEW

11 of 11 COMMON MISTAKES 1. Powering the thermostats prior to terminating the wires. If the bare wires touch damage may be done to the power supply,

Strona 4 - ATERIALS

2 of 11 THE 8800 THERMOSTATS DO NOT SUPPORT THE FOLLOWING FEATURES: Humidity Control: Humidity control is not supported. Legacy 8061 and 8062 support

Strona 5 - 8800COMMUNICATING THERMOSTAT

3 of 11 INSTALLATION OVERVIEW 1. Install the Aprilaire RS-485 thermostat network and control cables during the rough-in phase. Consult the Aprilaire

Strona 6

APRILA NOTES: 1. U2. U3. Ote4. Tdo BILL OF M #1 Thermos2 Duct/ReFlush MoWall Mo3TT SuppTrH Sup4 24 VAC 5 DistributAIRE 8800 SUp to 8 thermoUp to 4 dis

Strona 7 - THERMOSTAT PROGRAMMING

5 of 11 WIRING DIAGRAM 1: RS-485 CONNECTIONS TO THE THERMOSTAT AND THE OPTIONAL SUPPORT MODULE(S) The diagram below shows the communication connection

Strona 8

6 of 11 WIRING DIAGRAM 2: RJ-45 CONNECTOR PINOUTS

Strona 9

7 of 11 THERMOSTAT PROGRAMMING Once the thermostats are powered up and running properly, you need to make a few changes to the thermostat settings to

Strona 10 - CONFIGURATION DETAILS

8 of 11 TABLE 2: OTHER THERMOSTAT SETTINGS In addition to the standard settings listed above, there may be situations that require additional changes

Strona 11 - COMMON MISTAKES

9 of 11 Table 2: Aprilaire Model 8800 thermostat settings, showing factory defaults and g! standards. Note the comments to the right which indica