ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA
tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: elan@elanhomesystems.com
©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.
Integration Note
Manufacturer: Aprilaire
Model Number(s): 8800 Thermostat
Minimum Core Module Version: g! 5.4.104
Document Revision Date: 2/14/2013
OVERVIEW AND SUPPORTED FEATURES
THE 8800 THERMOSTATS SUPPORT THE FOLLOWING FEATURES:
Temperature Control: Temperature control can be managed by schedules tied to house modes or by
manual control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold).
Temperature can be shown as either Fahrenheit or Celsius on the viewer interface.
Mode Control: The climate system can be set to run in the following heating and cooling modes: Heat
only, Cool only, Auto Heat Cool, Emergency Heat or Off.
Fan Mode Control: Systems that have a fan can be set to run in Automatic, Continuous or Circulate
mode.
History View: The history view shows the inside temperature, outside temperature, unit run and fan run
times, and cooling and heating set points.
Schedule Control: Multiple schedules can be set using the Viewer software and configured using the
configurator. Up to 10 schedules can be created and are tied to the system mode.
Outside Air Temperature: The outside air temperature can be obtained from the weather information on
the web, a sensor connected to the thermostat, or monitored using an 8081 or 8082 Support Module. The
outside air temperatures can be displayed in real-time or tracked in history for each thermostat in the
Viewer.
Humidity Display: Although humidity control is not supported, the humidity value can be obtained from a
humidity sensor in the 8800 in the thermostat and humidity mode; from a humidity sensor in the 8082, or
from the web. You can display the value on the history graph; on a custom graph using a Graph View
control, or as a custom text display using the Numeric text control. Note: If a thermostat is configured as a
humidistat, then it must be removed from all interfaces.
Auto Time and Date: The g! system will automatically update the time and date on the thermostats
including daylight savings time changes.
Auto Thermostat Detection: The g! system will automatically detect all the thermostats connected to
system, along with each thermostat’s ID (number).
Celsius and Fahrenheit: Aprilaire Thermostats support displaying Temperatures in C or F both at the
stat and in the g! system in whole number values. Decimal place display and control is not supported for
these thermostats.
Remote Room Temp Sensor connected directly to 8800 Thermostat: The 8800 can be configured to
utilize a remote temperature sensor in place of its on board sensor. The sensor connects directly to its T1
& T2 terminals. When properly connected and configured this sensor will override the onboard sensor
and the thermostat then reports the remote sensor value to the system controller as its room temperature
value. Please refer to the Aprilaire documentation for setup information.