Automatic
Digital Humidifier Control
Safety and Installation Instructions
WARNING
ATTENTION INSTALLER: This product must be
installed by a qualified heating and air conditioning
contractor. Failure to do so could result in serious
injury from electrical shock.
READ COMPLETE INSTALLATION INSTRUCTIONS
AND TEMPLATE BEFORE STARTING.
Przeglądanie stron 0
1 2 3 4 5 6 ... 14 15

Podsumowanie treści

Strona 1 - Digital Humidifier Control

AutomaticDigital Humidifier ControlSafety and Installation InstructionsWARNINGATTENTION INSTALLER: This product must beinstalled by a qualified heatin

Strona 2 - INSTALLATION

1918OUTDOOR TEMPERATURESENSOR OR MANUALMODE RESISTORR C A B ODT CfW/GADHC TERMINAL STRIPH24 VACTRANSFORMERFURNACEBLOWERMODEL 50COMMONUSING MODEL 50 CU

Strona 3 - Water Panel

21201. Replace the cover by snapping it into the Humidifier Controlbase. Also replace the knob onto the Control.2. Restore power to the heating system

Strona 4 - CONTROL REPLACEMENT:

2322TROUBLESHOOTINGApplies to both Automatic and Manual Operation unlessindicated otherwise.TABLE 1Outdoor Temperature (°F) Resistance (kΩ) ±10-30 231

Strona 5

2524SYMPTOMHumidifier does not operate in “Test/Reset” modeTROUBLESHOOTING PROCEDURE• Make sure that the blower is operating and the HVACsystem is cal

Strona 6 - Mode Switch

2726SYMPTOMHumidifier operates only in “Test/Reset” mode• If outdoor temperature is greater than 60°F or less than -30°F, the Humidifier Control will

Strona 7 - HW/G CfODTBACR

28RESEARCH PRODUCTS CORPORATIONP.O. BOX 1467 • MADISON,WI 53701-1467Call 800/334-6011 • FAX 608/257-435710007267 11.07 B2204285BSYMPTOMHumidifier or

Strona 8 - BLOWER OPERATION (FIGURE K)

32Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3System Checkout . . . . . . . . . . . . . . . . .

Strona 9 - OPERATION (FIGURE L)

54STEP 2: Disassemble the Humidifier ControlRemove the knob. Remove the cover by pulling at the bottom andswinging it out and upward.STEP 3: Check the

Strona 10

76STEP 5: Determine Location for Humidifier Control and Mount ControlHumidifier Control must be mounted on the Return Duct, at least6 inches upstream

Strona 11 - SYSTEM CHECKOUT

98Figure D – Fiber Board Duct Mount90-1203CONTROL BOARDCOVERKNOBBASE PLATERETURN DUCTRETURNDUCTSHEET METALPLATECUT OPENING INRETURN DUCTSHEET METAL PL

Strona 12 - (CONTINUED)

1110STEP 8: Alternate Location for Outdoor Temperature SensorThe Sensor can also be mounted in the center of either:• PVC fresh air intake pipe for th

Strona 13

1312Installing the Humidifier Control forManual OperationIf it is not feasible to install the OutdoorTemperature Sensor, the Humidifier Control can be

Strona 14

FURNACE ACCESSORYTERMINALSTERMINALS MAY BE LABELED:“HUM”, “ACC” OR “EAC”24 VACTRANSFORMERHADHC TERMINAL STRIPW/G CfODTBACROUTDOORTEMPERATURE SENSOROR

Strona 15 - RESEARCH PRODUCTS CORPORATION

1716COMMONFURNACETERMINALSTRIPRWYGOUTDOOR TEMPERATURESENSOR OR MANUALMODE RESISTOR24 VACTRANSFORMERHADHC TERMINAL STRIPW/G CfODTBACR90-122424 VACTRANS

Komentarze do niniejszej Instrukcji

Brak uwag